AGV super capacitor module

AGV super capacitor module

  • Cname:Super capacitor module
  • Views:Times
  • Release date:2022-10-09 14:07:26
  • Content
  • Features
  • Parameter

Overview

       AGV supercapacitor module is to connect several supercapacitors in series and cooperate with voltage equalization and discharge voltage stabilization system. The birth of super capacitor module makes up for the defects of energy storage devices such as lead-acid batteries; The utility model solves the problem that the use efficiency of the lead-acid battery is greatly reduced under the outdoor cold conditions; Moreover, the super capacitor module not only has all the characteristics of the super capacitor monomer, but also has the function of monitoring the working state, which can better realize maintenance free and easy maintenance.

Basic parameters:

project

standard

size

335mm*180mm*180mm

weight

15kg

Rated Capacity

22Ah

Rated voltage

48V

voltage range

Charge cut-off voltage: 58.8V

Discharge cut-off voltage: 35V

Current range

Charging current 50A

Discharge current 50A

BMS model

F702-20100-2X

communication

485

Communication wiring

DB9 Female 2-A 3-B

Internal resistance (DCIR)

≤170mΩ

Current terminal

GRIDPOWER MPC50A600V Grey

Cycle life (room temperature)

3000th order (≥80%, 100% DOD) @ 20 ± 5 ℃

Discharge temperature

, -30℃~60℃

charging temperature

, -30℃~60℃

Product electrical properties

project

testing method

standard

Rated Capacity

After standard charging, leave the battery open circuit at 25℃±5℃ for 1~4h,
Then stop the test when the current is discharged to the cut-off voltage with 0.5C(A), and count the
Calculate the discharge capacity (in Ah).

0.5C≥22Ah

High temperature capacity

1. After standard charging, open the battery pack and place it in a high temperature box and set the temperature.
480min after the preset temperature is stable;
2. 0.2C (A) constant current discharge to cut-off voltage, calculate discharge capacity

The discharge capacity at different temperatures satisfies:
≥98% rated capacity@45℃;
The temperature setting should not exceed ±2°C

low temperature capacity

1. After standard charging, place the open circuit in the low temperature box and set the temperature.
Set aside for 960min after the temperature is stable;
2. 1C (A) constant current discharge to cut-off voltage, calculate discharge capacity

The discharge capacity at different temperatures satisfies:
≥90% rated capacity@-10℃;
≥80% rated capacity@-20℃;
≥70% rated capacity@-30℃;
The temperature setting should not exceed ±2°C

Normal temperature cycle life

25℃±5℃ ambient temperature
  Test Conditions:
Charging: 0.5C to 58.8V
Discharge: 1C to 35V
When the discharge capacity drops to 80% of the initial capacity, all
The number of cycles completed is defined as the cycle life of the cell
  Life

≥3000

充电.jpg

Precautions

Please observe the following safety regulations when using batteries. Misuse of the battery can cause the battery to overheat, swell, and catch fire and cause serious injury.  

ØDo not put the battery in fire or heat the battery  

Ø Do not reverse the battery so that the polarity of the battery is reversed  

ØDo not use metal objects ( such as wires, etc. ) or conductive materials ( such as carbon rods, etc. ) to connect the positive and negative poles of the battery  

Ø Do not carry or place the battery with necklaces, hairpins or other metal objects  

Ø Do not use hard objects ( such as nails, etc. ) to puncture the battery, do not use a hammer to hit the battery, do not step on the battery, do not collide strongly  

or shock battery  

Ø Do not put the battery in water or other solvents, and do not place the battery in a particularly humid environment for a long time  

超级电容模组应用.jpg

Do not disassemble or modify the battery. The battery has a protective device that, if damaged, could cause the battery to heat up, swell, or catch fire during use.

Do not place batteries near fires, stoves, or other hot objects. Do not expose the battery to strong sunlight.

The use of the battery by children should be carried out under the supervision of an adult to ensure that the battery is used correctly according to the user manual.  

When the battery is scrapped, it needs to be sent to a special place for recycling.  

When using, charging, or placing the battery, if the battery emits an odor, becomes extremely hot, swells, discolors, or deforms  

If any abnormal phenomenon occurs, please stop using it immediately. When something like this happens, you should contact your local dealer or Yukun Technology.

Do not put batteries in microwave ovens, high pressure containers or induction cookers.  

In case the liquid from the battery leaks into the eyes, please do not rub the eyes, rinse with clean water and go to the hospital immediately to avoid eye damage  

eye damage.  

Charge

recharging current

The charging current shall not exceed the charging current specified in this standard. Charging with a current higher than the recommended value may cause  

Charge and discharge performance, mechanical performance and safety performance issues, and may cause heat generation or leakage.  

Charging voltage

The charging voltage shall not exceed the rated voltage specified in this standard. 58.8V is the limit of charging voltage, the design of the charger should meet the  

this condition. When the cell voltage is higher than the rated voltage value, it may cause problems in the charging and discharging performance, mechanical performance and safety performance of the cell.  

May cause heat generation or leakage.

charging temperature /

The battery must  -30 ℃ ~60 be charged within the ambient temperature range of

Reverse charging prohibited /

Correctly connect the positive and negative poles of the battery, and reverse charging is strictly prohibited. If the positive and negative poles of the battery are reversed, the battery will not be able to be charged. At the same time, the opposite  

Charging will reduce the charging and discharging performance and safety of the battery, and will cause heat generation and leakage.

discharge

Discharge current /

The discharge current must not exceed the discharge current specified in this standard. Discharging with a large current will cause the capacity of the cell to decrease sharply and cause overheating.  

Discharge temperature /

The battery must be within the ambient temperature range of -30℃~60 ℃ discharged

overdischarge /

It should be noted that during long periods of non-use of the battery, it may be in some overdischarged state with other self-discharge characteristics. To prevent discharge from occurring , the battery should be charged regularly. Overdischarge will lead to the loss of cell performance and battery function.