  • Parameter

Product introduction:

        Yukun Farad capacitor, also known as double-layer capacitor, gold capacitor and supercapacitor, is a chemical element developed from the 1970s and 1980s. Supercapacitors store energy through polarized electrolytes without chemical reaction, and the process of energy storage is reversible, which is precisely because this supercapacitor can repeatedly charge and discharge hundreds of thousands of times. The difference between farad capacitance and ordinary capacitance is the difference in capacity. The capacity of ordinary capacitor is between 10000 and 40000 microfacies, and the capacity of super capacitor can reach thousands of farads, 1 farad=1 million microfacies, so the super capacitor is also called farad capacitance. Farad capacitor belongs to double-layer capacitor. It is one of the double-layer capacitors with large capacity that have been put into mass production in the world. Its basic principle is the same as other types of double-layer capacitor. It uses the double-layer structure composed of activated carbon porous electrode and electrolyte to obtain large capacity

Product specification:

model

Rated voltage V

Capacity F

Internal resistance Ω1KHz

24h leakage current uA

Product Size

Diameter D±0.5 (mm)

Length H±0.5 (mm)

Pitch ±0.5 (mm)

YKY5R5H104

5.5

0.1

50

5

11.5

4.5

11

YKY5R5H224

5.5

0.22

40

5

11.5

4.5

11

YKY5R5H334

5.5

0.33

40

8

11.5

4.5

11

YKY5R5H474

5.5

0.47

20

8

11.5

4.5

11

YKY5R5H105

5.5

1.0

15

10

19.5

6.5

19.5

YKY5R5H476

5.5

1.5

10

10

19.5

6.5

19.5

YKY5R5H477

5.5

4.0

10

15

24.8

6.7

24.8

Product Size:

Shenzhen Gold Capacitor


Product display:

5.5V1.5F H-3.jpg

5.5V0.1F5.jpg

Product use:

5.5V副本.jpg

Product packaging:

5.5V包装-1.jpg

testing method:

   1. Electrostatic capacity test method:

(1) Test principle

    The test of the electrostatic capacity of the supercapacitor is to use the method of constant current discharge of the capacitor, and calculate it according to the formula.

   C=It(U1-U2)

In the formula: C - electrostatic capacity, F;

       I-constant discharge current, A;

      U1, U2 - use voltage, V;

      t-Discharge time required for U1 to U2, S

(2), test procedure

   Charge the capacitor with a current of 100A, charge the capacitor to the working voltage and keep the voltage constant for 10 seconds, then discharge the capacitor with a current of 100A, take U1 as 1.2V and U2 as 1.0V, record the discharge time within this voltage range, and the total cycle Capacitance, take the average value.

2. Stored energy test

  (1) Test principle:

      The test of supercapacitor energy is carried out by the method of discharging the capacitor with constant power to 1/2 of the working voltage with the given voltage range of the capacitor. The output energy W of the capacitor is obtained from the relationship between the constant discharge power P and the discharge time T, namely:

          W=PT

  (2) Test procedure

     Charge the capacitor to the working voltage with a constant current of 100A, and then keep it constant until the charging current drops to the specified current (10A for traction type, 1A for start-up type), after 5 seconds of rest, discharge the capacitor with constant power to 1/2 of the working voltage, record Discharge time and calculate magnitude. Repeat the measurement 3 times and take the average value.

3. Equivalent series resistance test (DC)

  (1) Test principle

    The internal resistance of the capacitor is measured according to the sudden change of the voltage within 10 milliseconds of the capacitor disconnecting the constant current charging circuit. That is: in the formula:

     R - the internal resistance of the capacitor;

     U0 - capacitor cut off the voltage before charging;

     Ui - cut off the voltage within 10ms after charging;

     I - cut off the current before charging.

 (2) Measurement process

    Charge the capacitor with a constant current of 100A, disconnect the charging circuit when the charging working voltage is 80%, use a sampling machine, record the voltage change value within 10 milliseconds after the capacitor is powered off, and calculate the internal resistance, repeat 3 times, and take the average value.

4. Leakage current test

   After charging the capacitor to the rated voltage with a constant current of 100A, charge the capacitor with a constant voltage for 30min at this voltage value, and then leave it open for 72h. During the first three hours, the voltage value was recorded every minute, and during the remaining time, the voltage value was recorded every ten minutes.

  Calculate the self-discharge energy loss, SDLF=1-(V/VW)2, and the calculation time points are: 0.5, 1, 8, 24, 36, 72h.